Pressure Reducing Valves
max. operating pressure 500 bar
Pressure reducing valves keep the outlet pressure constant, also in case of a changeable, but always higher inlet pressure.
In hydraulic clamping systems, it is often necessary to pressurise single clamping elements or groups of clamping elements with reduced pressure.
This version with overpressure function compensates not only a pressure drop, but also a pressure increase above the preset pressure. For this purpose, a separate line to the reservoir must be provided.
Possible causes for a pressure increase are:
- Temperature increase (approx. 10 bar per 1°C)
- Force increase acts on the clamping cylinder
- Damage of the valve seat by swarf
Below the set outlet pressure, the hydraulic oil flows unhindered from P to A. In case of a pressure increase, the set spring force is overcome and a check valve cuts off the flow hermetically sealed. Thus, a further pressure increase is avoided, also in case of increasing inlet pressure p. In case of a pressure drop, e.g. because of a leakage at a cylinder, the check valve will be opened by a strong spring against the existing inlet pressure p. Hydraulic oil can continue flowing until the set outlet pressure is obtained.
If the outlet pressure increases, e.g. because of oil warming, a pressure relief valve opens. Thus, oil in the outlet pressure area can drain off by the reservoir line until the preset outlet pressure is more or less obtained and the pressure relief valve is closed. A return flow from A to P is only possible if the inlet pressure p drops below the set outlet pressure.
Item no. | CAD data | type | max. operating pressure [bar] | type | max. flow rate [l/min] | |
---|---|---|---|---|---|---|
Item no.
|
CAD data
|
Properties
| ||||
Item no.
|
CAD data
|
Properties
| ||||
Item no.
|
CAD data
|
Properties
| ||||
Item no.
|
CAD data
|
Properties
| ||||
Item no.
|
CAD data
|
Properties
| ||||
Item no.
|
CAD data
|
Properties
|
Item no. | CAD data | Description |
---|---|---|
Item no.
|
CAD data
|
Description
Connection block
for pressure reducing valve with manifold mounting
max. 500 bar, as per data sheet C2.9534
|
Item no.
|
CAD data
|
Description
Connection block
for pressure reducing valve with pipe thread
max. 500 bar, as per data sheet C2.9534
|
Item no.
|
Description
|
|
Item no.
|
Description
O-ring 6 x 1.5 mm, NBR
as per data sheet B1.828
|
|
Item no.
|
CAD data
|
Description
O-ring 8 x 1.5 mm, NBR
as per data sheet B1.5091
|
Item no.
|
Description
Kantseal sealing ring 23.52 x 1.68 mm
as per data sheet C2.9533
|
|
Item no.
|
Description
O-ring 18,77 x 1,78 mm
material: polyurethanes
as per data sheet C2.9534
|
|
Item no.
|
Description
Socket head cap screw
M6 x 40 mm - 12.9
as per data sheet C2.531
|
|
Item no.
|
CAD data
|
Description
Coupling nipple with DVV 6 bar
max. 500 bar, as per data sheet F9.425
|
Item no.
|
CAD data
|
Description
Coupling unit, complete
for double-acting cylinders
nominal volume 13 cm3
gas-preload pressure 100 bar
range of operating pressure 110 - 400 bar
as per data sheet F9.425
|